Fenzy
- Bioline Automatic Safety (B.A.S)
Air5000 Twin 15.5 kg Air5000
Single 12.5 kg
Identical design
with Bioline except
Automatic Safety option added.
The connection unit (4) on the belt
also includes :
An automatic permutator which ensures the supply of the mask from a
2 litre cylinder of air filled at 200 bar (5)
in case of failure of the main network ; this allows the wearer of the
B.A.S. 10 minutes to evacuate the toxic zone.
DESCRIPTION
MASK (1)
Panoramic with quick adjustable head straps. Its flexible internal profile
ensures tightness on all faces.
Internal half mask to prevent formation of mist, even during use at
low temperatures (- 30°). Speech diaphragm for use of telephone
or radio links.
AIR REGULATING SYSTEM (2)
Quick coupling demand valve 5000. As soon as it is connected on the
mask it releases and automatically maintains a slight positive pressure
ensuring excellent breathing comfort whatever working activities of
the wearer are. A push-button makes it possible to obtain an extra emergency
air flow.
The air inlet is automatically closed when the valve is uncoupled from
the mask.
BELT (3 and 4)
with the connection unit allowing the wearer to pull the air delivery
hose. It is fitted with a quick action automatic shut-off coupling.
CYLINDER
2 or 3 litre, 200 or 300 bar, light alloy or steel.
|