SPASCIANI
( RN )
To protect breathing pathways in case of oxygen deficiency or in environment
highly contaminated by breathable toxic.
Made in Italy
Includes Cylinder, Full face mask, Pressure reducer,
demand valve, unbreakable & anti static back plate.
Available in 200 bars - 6 litres
(30 minutes oxygen supplies) or
300 bars - 6 litres
(45 minutes oxygen supplies)
|
|

Pressure
Reducer Compact, reliable and balanced, it provides air a
pressure of 7 bars to the demand valve. As pressure varies, the pistons
modifies the reducer valve position, according to the required air flow.
The out pressure obtained remains stable whatever the air pressure in
the cylinder and the pressure reducer air flow maybe when the pressure
in the cylinder reaches 60 bars the warning whistle starts blowing.
|
COMMEINHES
REMCO Type C - 900
BACOU INTERSAFE - French
Availability : Steel or Aluminium Cylinder , include :
Full face mask
Back Frame. Ergonomically, light, made of green self
extinguishing polypropylene, shock and acid resistant,
the strap tightens one or two air cylinders of any types,
the padded shoulder straps are easily removable
and decontaminated, the left one is fitted with the HP gauge
and easily portable.
Cylinder. The C 900 Compressed air cylinders are
made of welds steel, aluminium alloy or composite material.
The water capacity ranges from 4 to 9 litres,
they can adapted to local standards for painting and
valve fitting.
Demand Valve
It Supplies the user with the air at 3.5 bars. It is connected to the
mask with a quick connector to the mask with a quick connector. With
the lateral push button the air supply can be stopped. At first inhalation
air is automatically supplied again. When pushing the centre of the
cover additional air is provided if needed.
|
Peripherals include
:
ACER Note 760I Computer with IBM PC
Auto run software on disk that allows simple inspection,
adjustment of the main
sub-assemblies and management of SCBA stocks
in addition to the complete SCBA inspection
Epson LX 800 Printer
|
Test Bench
is an open circuit Self Contained Breathing Apparatus (SCBA)
must be regularly inspected and maintained in good operational condition.
Test Bench consists of a breathing machine equipped with:
Double
action single bellows simulating human inhalation and exhalation
according to a sinusoidal cycle.
Dummy head with a pressure measuring tube on which
the SCBA mask is placed and tightened in position.
Electronic circuit to provide data to the computer.
Precision gauges for high, medium, and low pressures.
Cycle switch for 25 X 2 litres or 50 X 2 Litres.
|